DTM Generic System Flow Diagram
Download: DTM Generic System Flow Diagram.pdf
Technical Support
Subject
DTM Generic System Flow Diagram
Version Document Department Revision Details Revised by Tech Engineering Implemented
A EXT-DTM-003 Tech Document Release BDJ 28Sept2021 MSP 28 Sept2021
Knowledge Base: http://kb.vmacair.com/ Page 1 of 1
Email: tech@vmacair.com
Web: www.vmacair.com
Technical Support: 1(888)241-2289
Toll Free:1(800)738-8622 Fax: 1(877)740-3201
SYSTEM OR PARTS AFFECTED
• VMAC Direct-Transmission Mount 70 CFM air compressor systems (DTM).
• VMAC Direct-Transmission Mount air compressor & hydraulics (DTM -H)
OVERVIEW
The diagram below illustrates the generic hose connections and direction of flow in VMAC’s DTM 70 CFM air
compressor systems
Component locations may vary for each specific DTM air compressor system.
For additional information, refer to VMAC Installation Manuals for specific routing and installation instructions.
Hoses related to the air compressor system are the same in DTM and DTM-H.
Components of the hydraulic system in DTM-H are not shown in the above diagram.
Oil return
(cooled) cooler
to compressor
Oil return (hot)
AOST to Cooler
Air/oil discharge
(hot) compressor
to AOST
Air discharge
to tools
Engine coolant
3/16in pressure control
line - top of blowdown cap
to regulator
1/4in scavenging
line -bottom of
blowdown cap to
inlet
Regulator to inlet